In load monitoring testing using Simulink on DC loads, an error was obtained between the measurement results and the
various theories. The smallest error obtained is equal to 0.088737464% in the 15 Ohm shear resistance test, while the
biggest error is -22.68571337% is found in the monitoring of 30 Ohm sliding resistance load. In the AC load monitoring
test using Simulink, an error was obtained between the results of Simulink measurements with conventional
measurements using an ampere meter and an analog voltmeter. The smallest current measurement error is 3.433806453%
on the measurement of the lamp load current and the largest is 17.30705898% on the measurement of the fan load
current. While the smallest voltage measurement error is 0.164816128% on the measurement of the iron load voltage and
the largest is 0.928443504% on the fan load measurement. The measurement values of both current and voltage sensors
show varying measurements, this is due to the current sensor in dc load, the current obtained tends to be more stable, butfor loads with small currents the sensitivity level of the readings decreases. Whereas in the reverse AC load, the accuracy of the current sensor is not stable because the reading source is alternating current, but for large loads, the sensitivitylevel of the current readings improves.

Item Type: Article
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Jurusan Teknik Mesin > D4 Teknologi Rekayasa Energi Terbarukan
Depositing User: S.ST., M.T Marhatang Marhatang
Date Deposited: 27 Jun 2023 05:54
Last Modified: 27 Jul 2023 13:42
URI: https://repository.poliupg.ac.id/id/eprint/3964

Actions (login required)

View Item
View Item